The price difference between 656 and 868 twin wire fence panels can be easy to justify on paper, but whether the heavier specification is worth paying for depends on the job. A school boundary, a factory perimeter, and a site exposed to repeated attempts at cutting the fence may have very different requirements.
The two specifications use different wire diameters: 656 has 6 mm horizontal wires and 5 mm vertical wires, while 868 uses 8 mm horizontal wires and 6 mm vertical wires. The larger wires generally give 868 panels greater rigidity and make the horizontal wires more difficult to cut, but they also add steel weight and cost. Neither specification guarantees a particular level of security on its own.
Before choosing, compare the intended use, panel dimensions, post and fixing system, and the complete quoted price. The following sections explain where the differences matter and how to avoid paying for a specification your project may not need.
What Is a Twin Wire Fence?
Twin wire fence is a type of welded mesh fencing system with two horizontal steel wires and one vertical wire at each junction. The double wire construction makes the panels stronger than many standard single wire mesh fences and the open mesh design allows the boundary to be seen through and air to flow through.
Also called a double wire fence or 2D panel fence, this type of fencing is often used around schools, factories, car parks and commercial properties. It defines the perimeter without obscuring the view of the surrounding area. It is a practical choice for sites where visibility is important. The panels are attached to steel posts by means of clamps or brackets and the height and coating of the fence are chosen to satisfy the site requirements.
The paired horizontal wires give the panels resistance to bending, but the performance is more than the mesh itself. Post strength, fixing points and the quality of the installation all affect the stability of the finished fence.

What Do 656 and 868 Stand for in Twin Wire Fence Panels?
The numbers represent the diameter of the steel wires used in the panel, in millimetres. The first and last numbers are the two horizontal wires and the middle number is the vertical wire.
- 656 twin wire fence: 6 mm horizontal wires and 5 mm vertical wires.
- 868 twin wire fence: 8 mm horizontal wires and 6 mm vertical wires.
Both use two horizontal wires welded to each vertical wire, but the 868 panel uses thicker steel throughout.

656 vs 868 Twin Wire Fence: Key Differences
The main differences are in the rigidity of the panel, damage resistance and cost. Here’s how the two specifications compare.
| Feature | 656 Twin Wire Fence | 868 Twin Wire Fence |
| Wire diameter | 6/5/6 mm | 8/6/8 mm |
| Panel rigidity | Suitable for many general fencing applications | Greater rigidity with comparable panel dimensions |
| Panel weight | Lighter | Heavier |
| Material cost | Generally lower | Generally higher |
| Typical use | Schools, commercial sites, and general perimeter fencing | Industrial sites and projects requiring greater panel rigidity |
Actual performance and pricing depend on panel dimensions, steel grade, coating, and the complete fencing system.
Wire Diameter and Panel Rigidity
The most obvious difference is the wire diameter. The 868 panel is generally stronger than a comparable 656 panel, because of the thicker horizontal and vertical wires.
This can be important for larger or taller fence panels, where rigidity is an important consideration. However, panel width, mesh size, and the way the fence attaches to its posts also affect how much it flexes.
Strength and Security
Thicker wires make an 868 panel more difficult to cut through than a comparable 656 panel, all else being equal. This may be useful where tamper resistance is a concern.
That said, a stronger panel doesn’t guarantee a stronger fence. Post strength, fixing points, fence height, installation all matter. For sites with specific security requirements, evaluate the entire system instead of selecting based solely on wire diameter.
Weight & Price
868 fencing usually weighs more and costs more than 656, because there is more steel in each panel. Heavier panels can also mean more care in handling and installation.
Additional cost may be justified when additional rigidity or cutting resistance is important. 656 is also a practical trade-off between performance and cost for projects with less stringent demands. When comparing quotes make sure panel dimensions, coatings, posts and fixings are the same.

When Should You Choose 656 or 868?
Not every fence needs the thicker wires used in an 868 panel. For many sites, 656 provides enough rigidity for everyday perimeter fencing. The extra steel in an 868 panel is worth considering when the fence needs to withstand greater physical stress or resist cutting.
656 Twin Wire Fencing
656 twin wire fencing is a practical choice for schools, office grounds, car parks and commercial properties that require a strong, visible boundary without the extra weight of 868 panels.
The lower steel content usually translates into lower material costs and easier handling in installation. If the site does not have any unusual security requirements and the fence meets the required height and performance requirements, there might not be a great deal of practical benefit to paying extra for 868.
868 Twin Wire Fence
868 twin wire fence is a good option for industrial premises, equipment compounds and other sites where a stiffer panel is desired. Its thicker wires generally provide greater rigidity and make the mesh harder to cut than a comparable 656 panel.
The extra cost makes sense when these benefits address a real site requirement. For projects with specified security standards, however, check the required test performance rather than assuming that an 868 panel automatically meets the standard.
Consider Fence Height and Security Risks
Fence height and site exposure can change which specification makes sense. Taller panels require different things from the posts and fixings, and sites at greater risk of climbing, cutting or impact may need more than a heavier mesh panel.
Before choosing a panel, consider how the fence will be used and what it needs to withstand.
- Fence height and panel width: Taller fences and wider spans might require stronger posts and tighter fixings to hold the panels steady.
- Security requirements: A fence intended to define a property boundary may not be adequate for a site where cutting, climbing or forced entry is an issue.
- Posts and installation: Even a rigid panel can underperform if the posts, clamps or ground foundations are not up to the task. Make sure the whole fence system is suitable for the location.
If the project has formal security requirements, use the specified fence design and test criteria to guide your choice. Wire diameter is an important starting point, but it should not be the only deciding factor.

2D vs Other Fence Types
Twin wire fencing is not always the right choice for every site. Some projects need stiffer panels, others require smaller mesh openings or a more economical way to enclose a large area. Before you decide on a specification, compare the key differences and check the details that matter when buying double wire fence.
| Fence Type | Key Feature | Common Applications |
| 2D Twin Wire Fence | Paired horizontal wires add rigidity to the welded mesh panel | Schools, factories, commercial premises |
| 3D Welded Mesh Fence | V-shaped bends reinforce the panel | Parks, residential boundaries, general perimeter fencing |
| 358 Security Fence | Narrow mesh openings make climbing and cutting more difficult | Prisons, secure facilities, high-security perimeters |
| Chain Link Fence | Flexible mesh that works well over long runs and uneven ground | Farms, sports grounds, large property boundaries |
For a typical commercial perimeter, 656 or 868 twin wire fencing may provide the rigidity you need. If limiting footholds and access through the mesh is important, consider 358 fencing. If cost and ease of installation are more critical in large areas, then chain link may be the more practical choice.
Installation and Practical Factors
Panel specifications are only part of the order. Post spacing, ground conditions, and fixing details can affect both installation costs and the stability of the finished fence.

Before requesting a quotation, check the following:
- Post spacing and foundations: These need to suit the panel dimensions, fence height, and ground conditions. Taller fencing may require stronger posts or deeper foundations.
- Fixings and accessories: Confirm that the clamps, brackets, and posts are designed to work together. Mismatched components can complicate installation.
- Coating: Hot-dip galvanizing provides corrosion protection, while a powder-coated finish adds a layer of color and protection. The right choice depends on the exposure conditions and finish requirements.
- Site layout: Slopes, corners, gates, and changes in ground level can affect panel quantities and installation work.
When comparing supplier quotations, make sure you are looking at the same panel size, wire diameters, coating, post specifications, and accessories. A lower panel price does not necessarily mean a lower installed cost.
Conclusion
The decision between 656 and 868 twin wire fencing comes down to what the fence needs to withstand. For everyday boundary fencing, 656 may offer enough rigidity without the extra material cost. Where a stiffer panel and greater resistance to cutting are important, 868 is worth the additional investment. The posts, fixings, fence height, and installation still need to match the site’s requirements.
With more than 20 years in the wire mesh and fencing industry, Dunqiang handles product development, manufacturing, and export orders for a range of fencing applications. If you’re sourcing twin wire fence panels for a project, share your specifications or drawings to discuss the right configuration and request a quotation.










